Spray Foam Insulation for Contractors
Stop bidding on price. Start selling comfort.
ComfortSeal gives your bid more to stand on: a homeowner-friendly name, a limited lifetime warranty on the foam, certification for your crew and technical support on the job.
R-values are installed values at the stated thickness from IAPMO ER-974 and ER-975, Table 1. The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.
The brand does the selling. You do the spraying.
Sell comfort, not specs
Homeowners glaze over at R-values. ComfortSeal's warm, residential-first brand turns your proposal into a comfort upgrade they understand at the kitchen table.
A deliberately simple lineup
ComfortSeal 500 open cell and ComfortSeal HFO closed cell cover every residential job. Less inventory to carry, fewer processing profiles to manage, and crews that master both fast.
Support behind every job
Direct technical support for processing and application questions, plus training and full documentation, for the moment a tough job site raises a question.
Everything you need to close the job
From the first sales conversation to the final inspection, ComfortSeal backs your bid at every step.
Homeowner-friendly brand materials
A comfort-first story your residential customers respond to — the difference between bidding on price and winning on trust.
Limited lifetime warranty
Certified installers can offer the ComfortSeal limited lifetime warranty on every qualifying project — on the foam, for the life of the home.
Documentation for inspectors & builders
Technical data sheets and evaluation reports (ER-974, ER-975) in the tech library — everything a code official or GC asks for.
Training & technical support
Certification for your crew, and real experts on call when a processing question comes up mid-job.
Two products. Two 1:1 systems. One proportioner.
Both ComfortSeal products run 1:1 by volume, so your proportioner stays at the same A-to-B ratio whichever foam is on the truck. What changes is heat and pressure, and those numbers come straight from the data sheets.
ComfortSeal 500
- ✓ The workhorse for interior walls, attics and bonus rooms · NRC 0.75, STC 39
- ✓ Processing pressure 1200–1350 psi
- ✓ Primary heater and hose 125–130°F
- ✓ Substrate and ambient above 32°F · substrate moisture below 18%
ComfortSeal HFO
- ✓ Class II vapor retarder (0.45 perms at 2 in.) · 210 psf wind uplift (UL 1897)
- ✓ Processing pressure 1200–1450 psi
- ✓ Primary heater and hose 110–120°F — do not recirculate
- ✓ Substrate and ambient above 45°F in summer, 14°F in winter · substrate moisture below 18%
R-values are installed values at the stated thickness from IAPMO ER-974 and ER-975, Table 1. The higher the R-value, the greater the insulating power. Ask your seller for the fact sheet on R-values.
What 1:1 means in practice
The A side and B side meter out in equal volumes, so your crew learns one mixing ratio for both products. When foam comes out off-ratio, the usual suspects are material temperature, a pressure imbalance or a supply problem, which is why the ranges above belong on every job-start checklist.
Why two products keep the rig simple
Two sets of drums, two sets of settings. When you change products on the same rig, reset heat and pressure to the new range, and remember the HFO data sheet says not to recirculate. Processing question mid-job? That's what technical support is for.
Use the warranty to win the job, and explain it straight
Homeowners comparing three quotes rarely compare R-values. They compare who they trust. A warranty on the foam for the life of the home is easy to understand, as long as you describe it accurately.
Put it on the proposal
Name ComfortSeal, the product going into each area, and the limited lifetime warranty as its own line. Quote R-values from the report tables with the R-value calculator, never per-inch figures multiplied out.
Say what it covers
The warranty covers the foam itself, for the life of the home, when a certified ComfortSeal installer does the work. Your workmanship is yours to stand behind. Send homeowners to the warranty page for the details.
Leave the paperwork with the job
Coverage depends on a certified install. Note the product and installed thickness on the invoice, and leave the homeowner the data sheets from the tech library for their house records.
From first call to first certified job
1 · Start the conversation
Begin on the training page or contact our team. Tell us about your company, your rig and the work you do, and we'll explain how enrollment works today.
2 · Enroll your crew
Enroll each crew member who will spray ComfortSeal. Training covers application techniques, safety, building science and code compliance.
3 · Get certified
Certification lets your company order product, offer the limited lifetime warranty on qualifying projects and call on technical support.
4 · Get found
Certified companies are listed in the ComfortSeal installer network, which homeowners reach through Find an Installer.
One certification covers everything
Certification covers application techniques, safety, building science, and code compliance; it runs in our online installer portal, at your crew's pace. Pass it and your company can order product, offer the warranty, and lean on our support.
Start today, spray this season
Contact our team to enroll, and get your crew certified on your own schedule.
Register your company →What contractors ask before switching
How does the warranty work for my customers?+
Certified installers can offer the ComfortSeal limited lifetime warranty on every qualifying project. It covers the foam for the life of the home; installation workmanship stays with you.
What support do I get on the job site?+
Certified installers get direct technical support for processing and application questions, plus full documentation — technical data sheets and evaluation reports (ER-974 and ER-975) for inspectors and builders.
Why only two products?+
The lineup is deliberately simple: ComfortSeal 500 open cell for air sealing and sound control, and ComfortSeal HFO closed cell for the higher R-value per cavity depth of the two and vapor control. Two products cover every residential job.
Can I run both products through the same proportioner?+
Yes. Both are 1:1 by volume, so the ratio stays the same. The settings don't: ComfortSeal 500 processes at 1200–1350 psi with heater and hose at 125–130°F, while ComfortSeal HFO runs at 1200–1450 psi with heater and hose at 110–120°F and should not be recirculated. Reset heat and pressure when you change products.
Does the warranty cover my installation work?+
No. The limited lifetime warranty covers the foam, for the life of the home, and it depends on installation by a certified ComfortSeal installer. Workmanship stays the installing contractor's responsibility. The full written terms are being finalized; ask our team and we'll walk you through what's covered.
Add ComfortSeal to your lineup